Overhead Twisted Cable

Covered Line Wire is used primarily for 600V overhead secondary distribution lines. Its not an electrically insulated conductor and is usually treated as bare conductor when installed.

Overhead Twisted Cable

Covered Line Wire is used primarily for 600V overhead secondary distribution lines. It's not an electrically insulated conductor and is usually treated as bare conductor when installed.


Standards:

ASTM B-230 - Aluminum Wire 1350-H19 for Electrical Purposes

ASTM B-231 - Concentric-Lay-Stranded Aluminum Conductors

ASTM B-232 - Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR)

ASTM B-399- Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors

ICEA S-61-402-: Thermoplastic-insulated Wire And Cable For The Transmission And Distribution Of Electrical Energy

ICEA S-66-524-XLPE Insulated Wire and Cable For the Transmission and Distribution of Electrical Energy 

图片2.png

Parameter

Covered Line Wire

Rated Voltage

0.6/1kv

Specification

ABC

Structure

AWG or kcmil

Carrying wire coreACSR)

Phase Conductor

Phase Insulation

Overall


Dia

Cable


Steel

Aluminium

Aluminium

xlpe

Dia

Dia

Weight


No.

Dia

No.

Dia

Dia

No.

Dia

Dia

mm

mm

mm

kg/km

3*6AWG+1*6AWG

1

1.68

6

1.68

5.04

1

4.11

4.11

1.14

6.4

14.62

221

3*6AWG+1*6AWG

1

1.68

6

1.68

5.04

7

1.55

4.66

1.14

6.95

15.62

227

3*4AWG+1*4AWG

1

2.12

6

2.12

6.36

1

5.19

5.19

1.14

7.48

17.37

331

3*4AWG+1*4AWG

1

2.12

6

2.12

6.36

7

1.96

5.88

1.14

8.17

18.62

338

3*2AWG+1*2AWG

1

2.67

6

2.67

8.02

7

2.47

7.42

1.14

9.71

22.41

511

3*1/0AWG+1*1/0AWG

1

3.37

6

3.37

10.11

19

1.89

9.47

1.52

12.52

28.77

824

3*2/0AWG+1*2/0AWG

1

3.78

6

3.78

11.35

19

2.13

10.63

1.52

13.68

31.61

1015

3*3/0AWG+1*3/0AWG

1

4.25

6

4.25

12.74

19

2.39

11.94

1.52

14.99

34.82

1254

3*4/0AWG+1*4/0AWG

1

4.77

6

4.77

14.31

19

2.68

13.4

1.52

16.45

38.42

1554

3*336.4+1*336.4

1

3.47

18

3.47

17.36

19

3.38

16.9

2.03

20.96

48.43

2321

3*336.4+1*4/0AWG

1

4.77

6

4.77

14.31

19

3.38

16.9

2.03

20.96

46.59

2221


  • Construction:
    Conductors are 1350-H19 Aluminum Wire, 6201-T81 Aluminum Alloy or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene(HDPE) or cross-linked polyethylene(XLPE).

Process

Each process will be checked by our engineer during production.

  • 矩形1.png

    01

  • 矩形2.png

    02

  • 矩形3.png

    03

  • 矩形4.png

    04

  • 矩形5.png

    05

  • 矩形6.png

    06

Certificate

message

Thank you for your interests in Ali-Cable Group, Pease feel free to submit your inquiry in the form below. We will reply you with detail ASAP.