MV Covered Aluminum Cables

The 15KV/25kV/35KV voltage class XLPE covered aluminum cable is constituted by a compact round conductor, composed by aluminum strands, blocked or not, and with a cross-linked polyethylene (XLPE) covered in black or gray color, with special characteri…

MV Covered Aluminum Cables

The 15KV/25kV/35KV voltage class XLPE covered aluminum cable is constituted by a compact round conductor, composed by aluminum strands, blocked or not, and with a cross-linked polyethylene (XLPE) covered in black or gray color, with special characteristics to be resistant against electric tracking and UV-rays. As XLPE is a thermoses material, it enables operation up to 90°C continuously implying in higher capacity when compared to the thermoplastic materials.
The main application for covered aluminum cables is on compact overhead, primary power distribution, medium-voltage networks located in urban and wooded areas. These cables are an excellent technical and economic option for companies all over the world, since they feature such advantages as low manufacturing cost and ease of installation.


Parameter

IEC 60502 6.35/11kV ABC for Overhead Distribution Lines

Number of Cores

Phase Conductor

Messenger Suspension Unit

Continuous

xNominal

Stranding

Nominal

Maximum

Stranding

Nominal


current rating

Cross Section

Sectional

Conductor

Sectional

Breaking

at 300°C


Area

Resistance

Area

Load

ambient temp

No.xmm2

No.xmm

mm2

Ω/Km

No.×mm

mm²

KN

A

3X50 + 1X25

19/1.78

50

0.641

7/3.0

50

60

116

3X70 + 1X50

19/.14

70

0.443

7/3.15

50

62

210

3X95+ 1X50

19/2.52

95

0.32

7/3.0

50

60

173

3X185+1X120

37/2.52

185

0.164

7/4.67

120

150

259

3X150 +1X50

37/2.25

150

0.206

7/3.15

50

62

365

3X240 +1X50

61/2.25

240

0.125

7/3.15

50

62

500


Other cross-sections can be offered upon request.



IEC 60502 19/33 kV ABC for Overhead Distribution Lines

Number of Cores

Phase Conductor

Messenger Suspension Unit

Continuous

xNominal

Stranding

Nominal

Maximum

Stranding

Nominal


current rating

Cross Section

Sectional

Conductor

Sectional

Breaking

at 300°C


Area

Resistance

Area

Load

ambient temp

No.xmm2

No.xmm

mm2

Ω/Km

No.×mm

mm²

KN

A

3X50 + 1X50

19/1.78

50

0.641

7/3.0

50

60

165

3X150+ 1X50

37/2.25

150

0.206

7/3.0

50

60

315

3X185+1X70

37/2.52

185

0.164

7/3.57

70

91

355

3X70 +1X50

19/2.14

7

0.443

7/3.15

50

62

250

3X150 +1X50

37/2.25

150

0.206

7/3.15

50

62

370


Other cross-sections can be offered upon request.